Restaurant Kitchen Design and Exhaust Rules in Dubai

How to design a commercial restaurant kitchen in Dubai that passes inspection and works on a busy service: workflow zones, hygiene finishes, hoods, grease ducts, make-up air, fire suppression, odor control, gas and indicative 2026 costs.

Updated 13 Oct 20267 min read
Restaurant Kitchen Design and Exhaust Rules in Dubai
In this article

Quick answer

How to design a commercial restaurant kitchen in Dubai that passes inspection and works on a busy service: workflow zones, hygiene finishes, hoods, grease ducts, make-up air, fire suppression, odour control, gas and indicative 2026 costs. Every good kitchen design begins with the menu, not the floor plan.

Last updated:

Restaurant kitchen design in Dubai has to satisfy two sets of rules at once: food safety requirements enforced by Dubai Municipality, and fire and life safety requirements enforced by Dubai Civil Defence, plus the landlord's technical rules for exhaust routes and odor control. In practice that means a one-way workflow from delivery to service, washable and sealed finishes, a correctly sized hood with a fully enclosed grease duct, make-up air, an approved wet chemical suppression system over cooking equipment and a grease interceptor on drainage. Indicatively, the kitchen exhaust, make-up air and suppression package alone often costs AED 60,000 to AED 250,000 in 2026, depending on the cooking line and duct route.

Start with the menu and cooking line

Every good kitchen design begins with the menu, not the floor plan. The menu determines the cooking equipment, which determines the hood length, exhaust volume, gas or electrical load, refrigeration and storage. Before drawings start, list:

  • Each cooking appliance (charcoal or gas grills, fryers, wok burners, tandoor, combi ovens, induction tops, pizza ovens) and its fuel.
  • Expected covers per hour at peak and the delivery-order volume, which is significant for many Dubai restaurants.
  • Prep methods: how much is prepared in house, how much arrives prepared, and whether you need separate raw meat, seafood, vegetable and pastry areas.
  • Storage needs: dry store, walk-in chiller, freezer and the number of deliveries per week.

A heavy charcoal grill or a row of wok burners needs a very different hood and duct system from an induction-based café kitchen. Getting this information right at the start avoids redesigns after approval drawings are submitted.

Kitchen workflow and zoning

Food safety inspectors look for a logical, one-directional flow that keeps raw and cooked food apart and separates clean and dirty activities. A typical sequence is:

  1. Receiving: close to the service entrance, with space to check deliveries and temperatures.
  2. Storage: dry store, chillers and freezers with separate shelving for raw and ready-to-eat items.
  3. Preparation: separate prep areas or dedicated sinks and boards for raw meat, poultry, seafood and vegetables, with hand-wash sinks close by.
  4. Cooking: the hot line under the hood.
  5. Plating and pass: a clean area between kitchen and dining or the delivery collection point.
  6. Dishwashing: a dirty return route that does not cross the clean pass, with pre-rinse, dishwasher and clean rack storage.
  7. Waste: a dedicated route and holding area for waste and used oil, away from food.

Delivery platforms add a new flow: drivers collecting orders should not enter the kitchen. A dedicated pickup window or counter near the entrance keeps them out of food areas and the dining room.

Hygiene finishes and fixtures

Dubai Municipality's food safety requirements expect surfaces that are smooth, durable, non-absorbent and easy to clean. Typical specifications include:

  • Floors: slip-resistant, impervious finishes such as anti-slip ceramic or quarry tiles with epoxy grout, or seamless resin flooring, with coved skirting at wall junctions and falls to floor drains.
  • Walls: glazed tiles, stainless steel cladding behind cooking and wash areas, or hygienic PVC wall sheeting.
  • Ceilings: washable, moisture-resistant panels or sealed gypsum with appropriate paint; no exposed fibrous materials above food areas.
  • Hand-wash sinks: dedicated basins with hands-free taps, soap and paper towel dispensers in each work area.
  • Stainless steel: food-grade stainless steel worktops, shelving and sinks.
  • Pest control: sealed penetrations, fly screens, insect killers away from food and sealed door bottoms.
  • Lighting: bright, shatter-protected light fittings.

Requirements evolve, so ask your consultant to check the current food code and any inspection checklist before finalizing specifications.

Kitchen exhaust rules: hoods, ducts and discharge

Kitchen exhaust is the most technically demanding part of a restaurant fit-out, and the most common cause of delays. While the exact requirements depend on the authority, the building and the landlord, these principles are widely applied:

Hoods

  • The hood should overhang the cooking equipment on all open sides and cover the full cooking line.
  • Grease-producing appliances need hoods with removable grease filters, typically stainless steel baffle filters, rather than mesh filters that trap grease and burn.
  • The exhaust volume is calculated from the equipment type, hood style and length. Undersized systems leave smoke and heat in the kitchen; oversized systems waste energy and make doors hard to open.

Grease ducts

  • Ducts are normally made from heavier-gauge steel with continuous welded or liquid-tight joints, sloping back towards the hood or to grease drains.
  • They usually run inside a fire-rated enclosure or are wrapped with an approved fire-rated wrap where they pass through the building.
  • Access doors are needed at intervals and at changes of direction so the ductwork can be cleaned.
  • The duct route must avoid other services where possible and must not pass through areas that would compromise fire separation without protection.

Discharge point

  • Discharge is typically at roof level or another approved point, away from air intakes, windows, balconies and neighboring properties.
  • Many landlords, especially in mixed-use buildings, require odor and smoke control equipment, such as electrostatic precipitator units, UV systems or carbon filtration, before the fan or discharge.

Fans

Exhaust fans rated for kitchen use are typically located near the discharge so ducts remain under negative pressure inside the building. Fan speed controllers let staff reduce extraction during quiet periods.

Make-up air and kitchen comfort

Every cubic meter of air extracted has to be replaced. Without planned make-up air, the kitchen pulls air from the dining room and corridors, doors slam, smoke spills from the hood and air conditioning works much harder. Good designs supply tempered or cooled fresh air close to, but not directly into, the hood, and keep the kitchen at a slightly negative pressure relative to the dining room so smells do not escape. In Dubai's climate, untreated outdoor air in summer is very hot and humid, so make-up air units with cooling or a heat-recovery solution are worth discussing with your MEP engineer.

Fire suppression and gas safety

  • Wet chemical suppression: cooking lines with grease-producing appliances normally require an approved automatic wet chemical system covering the hood, plenum, duct entry and appliances, with manual release stations and automatic fuel shut-off.
  • Fire alarm integration: suppression release usually signals the building fire alarm and shuts down gas supply and, where required, exhaust or supply fans in line with the approved fire strategy.
  • Gas systems: LPG or natural gas installations need approved design, certified installers, gas detection with automatic shut-off, and Civil Defence approval. Many malls and buildings have central gas systems with their own connection rules.
  • Extinguishers and fire blankets: wet chemical extinguishers suitable for cooking oil fires should be provided near the cooking line.

See our guide to Civil Defence approvals for fit-outs for the general process.

Drainage and grease interceptors

Kitchen drainage must pass through a grease interceptor sized for the kitchen's output, with space and access for regular emptying. Floor drains need traps and removable baskets. Dishwashers, combi ovens and ice machines need correct indirect connections. Landlords often have rules on where grease traps go and how often they must be serviced, with records kept for inspection.

Indicative costs for commercial kitchen works (2026)

These indicative 2026 ranges are for a typical 40 to 80 m² restaurant kitchen. They depend on menu, equipment, building constraints and landlord requirements. VAT at 5% applies.

ItemIndicative range (AED)
Hygiene finishes (floor, walls, ceiling)35,000 – 110,000
Hood, grease duct, fan and fire-rated enclosure45,000 – 180,000
Make-up air unit and ductwork20,000 – 90,000
Odor and smoke control unit25,000 – 120,000
Wet chemical suppression system15,000 – 50,000
Grease interceptor and drainage works10,000 – 45,000
Gas installation and detection15,000 – 70,000
Cooking, refrigeration and dishwashing equipmentPriced separately; often 150,000 – 600,000+

For the wider fit-out picture, read our restaurant fit-out requirements guide and our small café design guide.

Common kitchen design mistakes

  • Leasing a unit without an exhaust route: if the duct cannot reach an approved discharge point, the concept may not be viable or may need expensive odor control.
  • Adding equipment after approval: a new fryer or charcoal grill outside the hood or suppression coverage means redesign and re-approval.
  • Ignoring make-up air: kitchens become hot, smoky and uncomfortable, staff turnover rises and the AC bill grows.
  • Too few hand-wash sinks: a common inspection issue.
  • Forgetting maintenance access: ducts without access panels, grease traps under fixed equipment and filters that are hard to remove lead to poor cleaning and fire risk.
  • Underestimating delivery operations: no space for packing and driver collection creates congestion at the pass.

Maintenance after opening

Kitchen exhaust systems must be cleaned regularly, with frequency depending on cooking volume and type. Keep records of hood and duct cleaning, suppression system servicing, grease trap emptying and gas inspections; landlords, insurers and inspectors may ask for them. Filters should be cleaned daily or as often as the cooking requires. A planned preventive maintenance contract makes this predictable; our preventive maintenance checklist shows how scheduled maintenance is typically organized.

Key takeaways

  • Design from the menu: equipment drives hood size, exhaust volume, utilities and layout.
  • Plan a one-way workflow with raw and cooked separation and a separate delivery pickup point.
  • Use welded, enclosed grease ducts with access panels, an approved discharge point and odor control where required.
  • Provide make-up air, an approved wet chemical suppression system, gas detection and a correctly sized grease interceptor.
  • Keep maintenance records from day one.

Design your restaurant kitchen with FIXORA Decor

FIXORA Decor designs and builds restaurant kitchens and F&B fit-outs in Dubai, coordinating MEP engineers, kitchen suppliers and approvals. Message us on WhatsApp at +971501962136 or request a quote to review your unit and menu.

The information in this article is general guidance, not advice for your specific project. See our Terms.

Frequently asked questions

Cooking lines with grease-producing appliances normally require an approved automatic wet chemical suppression system covering the hood, duct entry and appliances, linked to fuel shut-off. It is reviewed and inspected as part of Civil Defence approval.
Typically at roof level or another approved point away from air intakes, windows and neighbors. Landlords in mixed-use buildings often also require odor and smoke control units before discharge.
As an indicative 2026 range, the hood, grease duct, fan and enclosure often cost around AED 45,000 to AED 180,000, with make-up air, odor control and suppression adding to that, depending on equipment and duct route.
Surfaces must be smooth, durable, non-absorbent and easy to clean, such as anti-slip tiles or resin floors with coved skirting, tiled or stainless walls, washable ceilings and food-grade stainless steel work surfaces.
It depends on cooking volume and type; heavy grease or charcoal cooking needs more frequent cleaning. Follow your landlord's and maintenance contractor's schedule and keep cleaning records for inspections.

Sources

Was this article helpful?

Get new articles by email

Practical tips now and then. Confirm by email, unsubscribe any time.

Need help with your project?

Our team is ready to help — get a free quotation today.

Or call us+971 50 196 2136

Serving